Type

Database

Creator

Date

Thumbnail

Search results

7 records were found.

A small series production of detector modules made of MicroStrip Gas Counters (MSGC) and a Gas Electron Multiplier (GEM) foil has been exposed to a high-intensity hadron beam. We report about the reproductibility and stability of the detector responses and about the occurrence and consequences of discharges in the detector. The interdependence of the four voltage differences used in the detector has been studied by simulation and with X-ray measurements. Rate dependence of the signal amplitude is observed. The behaviour of the MSGC+GEM is compared to that of a state-of-the-art MSGC. Influence of various parameters on the detector response is investigated.
Inelastic nuclear collisions of hadrons incident on silicon sensors can generate secondary highly ionising particles (HIPs) and deposit as much energy within the sensor bulk as several hundred minimum ionising particles. The large signals generated by these 'HIP events' can momentarily saturate the APV25 front-end readout chip for the silicon strip tracker (SST) sub-detector of the compact muon solenoid (CMS) experiment, resulting in deadtime in the detector readout system. This paper presents studies of this phenomenon through simulation, laboratory measurements and dedicated beam tests. A proposed change to a front-end component to reduce the APV25 sensitivity to HIP events is also examined. The results are used to infer the expected effect on the performance of the CMS SST at the future large hadron collider. The induced inefficienc...
Inelastic nuclear collisions of hadrons incident on silicon sensors can generate secondary highly ionising particles (HIPs) and deposit as much energy within the sensor bulk as several hundred minimum ionising particles. The large signals generated by these ‘HIP events' can momentarily saturate the APV25 front-end readout chip for the silicon strip tracker (SST) sub-detector of the compact muon solenoid (CMS) experiment, resulting in deadtime in the detector readout system. This paper presents studies of this phenomenon through simulation, laboratory measurements and dedicated beam tests. A proposed change to a front-end component to reduce the APV25 sensitivity to HIP events is also examined. The results are used to infer the expected effect on the performance of the CMS SST at the future large hadron collider. The induced inefficienc...
Want to know more?If you want to know more about this cutting edge product, or schedule a demonstration on your own organisation, please feel free to contact us or read the available documentation at http://www.keep.pt/produtos/retrievo/?lang=en